Symptom

Cement on the roof around the safety valve, the safety valve lifts at deliveries, or the pressure alarm stops deliveries early.

Likely causes

  1. Top filter blocked or blinded, often because the cleaning air is off or wet.
  2. Pressure sensor set at the same value as the safety valve, or its port is blocked.
  3. Silo overfilled because the high-level indicator failed or is too short.
  4. Tanker pressure too high, or residual tanker pressure vented into the silo.
  5. Inlet valve not failsafe, or its air line kinked to bypass it.

Most likely and cheapest to check first.

Checks

  1. Read the alarm log and delivery records. Treat any safety-valve lift as a near miss.
  2. Check the filter cleaning air is on and at 5–6 bar, and look at the cartridges.
  3. Check the set-points: pressure sensor about 40 mbar, safety valve about 50 mbar.
  4. Function-test the high-level indicator and the pressure sensor from ground level. A lamp test is not a test.
  5. Remove air or power from the inlet valve. It must close by itself.

Fix

  1. Clean or replace the filter cartridges; restore dry cleaning air.
  2. Correct the set-points; clean the sensor port.
  3. Clean the safety valve; replace springs and gaskets (about every 24 months).
  4. Replace a non-failsafe inlet valve with a failsafe-closed one.
  5. Post the delivery rules at the fill point and brief the drivers.

Stop the equipment if

The safety valve is seized, the high-level indicator does not alarm, or the inlet valve does not close on alarm. No deliveries until fixed.

Parts you may need

Six parts, one system

A safe delivery depends on six parts working together. The safety valve is only the last of them and should never open in normal use.

PartWhereCorrect setting
Top filterSilo roofPasses 1,700–2,000 m³/h; cleaning air working
Pressure sensorSilo roofAlarm at about 40 mbar; closes the inlet valve at once
High-level indicatorRoof, 1–1.5 m below the topAlarm at once; closes the inlet valve after about 30 s
Pressure relief valveSilo roofOpens at about 50 mbar
Inlet shut-off valveFill pointCloses by itself when air or power fails
Control panelFill pointAlarms, beacon, true ground-level test

A silo shell can be damaged above about 0.07 bar of internal pressure. A road tanker can deliver at up to 2 bar.

DANGERNever vent the tanker's residual pressure into the silo, and never leave a delivery unattended. A kinked or tied air line on the inlet valve defeats the protection.
COST OF NEGLECTA safety valve used as a normal vent packs with cement and finally does not open. The next mistake ends with the filter blown off the roof.
FIELD TIPPowder around the safety valve is a sign of over-pressurisation, not overfilling. Check that every fill point has an anti-whip restraint for the hose and the driver instructions posted: maximum pressure, what to do on an alarm, never vent into the silo, lock the fill point afterwards.