Safety valve blows at every delivery

⚠ STOP the equipment until this is fixed.

Open in the diagnosis tool
FILL M SCALE
Symptom
Safety valve blows at every delivery
Likely cause
Filter blinded, pressure sensor set equal to the valve, or tanker pressure too high.
Check
Filter condition; set-points must be 40 mbar (sensor) and 50 mbar (valve).
Fix
Clean or replace the filter, correct the set-points, brief the drivers.

Manual · Book 2 · § 13.1 · 4.1