BETONPARTSDiagnosis sheet · https://betonparts.com/en/faults/cement-silo/valve-blows/
Cement silos and screw conveyors · Filling and pressure
Safety valve blows at every delivery
⚠ STOP the equipment until this is fixed.
- Symptom
- Safety valve blows at every delivery
- Likely cause
- Filter blinded, pressure sensor set equal to the valve, or tanker pressure too high.
- Check
- Filter condition; set-points must be 40 mbar (sensor) and 50 mbar (valve).
- Fix
- Clean or replace the filter, correct the set-points, brief the drivers.
Manual · Book 2 · § 13.1 · 4.1
Parts you may need
⚠ Every look inside, turn by hand or open step means full lockout first. Never enter a silo or a bin with material in it.
Plant / site
Machine and serial no.
Date
Checked by
Findings and actions
Questions or parts: info@betonparts.com · WhatsApp +905073288473 · quote within 24 working hours