BETONPARTSDiagnosis sheet · https://betonparts.com/en/faults/water-hydraulics/no-water/
- Symptom
- Pump gives no water
- Likely cause
- Not primed, air leak in the suction, foot valve stuck, suction valve closed, or wrong rotation.
- Check
- Prime; check suction joints, foot valve, valves and rotation.
- Fix
- Prime; seal joints; free the valve; correct rotation. No water, no concrete.
Manual · Book 6 · § 12.1 · 3
Parts you may need
⚠ Every look inside, turn by hand or open step means full lockout first. Never enter a silo or a bin with material in it.
Plant / site
Machine and serial no.
Date
Checked by
Findings and actions