BETONPARTSSpare & wear parts
Wear parts in stock · Türkiye Quote within 24 working hours Dispatch within 24 h

Aggregate bins · Vibrator and sensors

Vibrator has no effect on flow

Open in the diagnosis tool
SANDGRAVEL
Symptom
Vibrator has no effect on flow
Likely cause
Too small, wrong place, or force set too low.
Check
Size and position against the sizing rule.
Fix
Resize or relocate the vibrator.

Manual · Book 4 · § 12.4 · 7.3

Parts you may need

Request the parts

⚠ Every look inside, turn by hand or open step means full lockout first. Never enter a silo or a bin with material in it.