BETONPARTSDiagnosis sheet · https://betonparts.com/en/faults/weighing/meter-air/
Weighing systems · Water and admixtures
Meter counts but less water arrives
- Symptom
- Meter counts but less water arrives
- Likely cause
- Air in the line, or worn meter.
- Check
- Weigh test against the meter.
- Fix
- Bleed the air; service the meter.
Manual · Book 3 · § 13.6 · 9.4
Parts you may need
⚠ Every look inside, turn by hand or open step means full lockout first. Never enter a silo or a bin with material in it.
Plant / site
Machine and serial no.
Date
Checked by
Findings and actions