- Symptom
- Door slow
- Likely cause
- Low oil, worn pump, relief valve leaking, throttle set wrong, or cold oil.
- Check
- Oil level; pressure on the gauge.
- Fix
- Top up; test pressure; service the valve; adjust the throttle.