BETONPARTSDiagnosis sheet · https://betonparts.com/en/faults/pneumatics/water-bowls/
- Symptom
- Water in FRL bowls every day
- Likely cause
- Dryer off, bypassed or failed, or drains blocked.
- Check
- Dryer dew point display; press each drain test button.
- Fix
- Repair the dryer and drains.
Manual · Book 7 · § 9.2 · 4
Parts you may need
⚠ Every look inside, turn by hand or open step means full lockout first. Never enter a silo or a bin with material in it.
Plant / site
Machine and serial no.
Date
Checked by
Findings and actions
Questions or parts: info@betonparts.com · WhatsApp +905073288473 · quote within 24 working hours